Volume 26, Issue 1 (3-2013)                   jdm 2013, 26(1): 64-70 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Bashizade H F, Molaei N, Teimoorinezhad A. Evaluation of vertical magnification of panoramic radiography by CT scan sectionsfor dental implant. jdm 2013; 26 (1) :64-70
URL: http://jdm.tums.ac.ir/article-1-9-en.html
Abstract:   (8361 Views)

Background and Aims: The Panoramic radiography is one of the routine techniques in implant imaging. Although there are some limitations with this technique, panoramic radiography is radiographic choice for basic evaluation for implant treatment. Many studies have been designed to determine magnification in panoramic images but most of them were performed on dry skulls or radiographic phantoms. In recent studies CT or CBCT are used as gold standard. The aim of this study was to determine vertical magnification of panoramic images using renovated CT sections in anterior and posterior regions of both jaws.

Materials and Methods: 30 panoramic radiographs (Planmeca EC or CC Proline) were selected from patients of implant department and Particular anatomic landmarks were selected in those images. Vertical dimensions of these landmarks were measured in both panoramic and renovated cross sectional CT images by a digital caliper and vertical magnification was calculated as the ratio of image dimensions to the real dimensions.

Results: The mean vertical magnification of panoramic radiographs in anterior and posterior maxillae were 1.22±0.02 and 1.16±0.02, respectively. The mean vertical magnification of panoramic radiograph in anterior and posterior mandible were 1.20±0.02 and 1.13±0.02, respectively. The differences between magnification in mandible and maxillae were significant (P<0.001). The differences between magnification in anterior and posterior regions of both jaws were not significant (P=0.11).

Conclusion: Vertical magnification of panoramic images (Planmeca EC or CC Proline) in different regions in both jaws were between 1.13 to 1.22.

Full-Text [PDF 252 kb]   (3586 Downloads)    
Type of Study: Research | Subject: general
Received: 2012/08/10 | Accepted: 2013/04/26 | Published: 2013/09/15

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb