Volume 29, Issue 4 (1-2017)                   jdm 2017, 29(4): 247-252 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Karami M, Roshanaei G, Shokri A, Pasandi N. Validation methods to measure the length of the teeth-canal: A methodological study. jdm 2017; 29 (4) :247-252
URL: http://jdm.tums.ac.ir/article-1-5586-en.html
1- Member of Modeling of Non Communicable Diseases Research Centre, Hamadan University of Medical Sciences, Hamadan, Iran
2- Associate Professor, Department of Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
3- Associate Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
4- MSc. Student, Department of Epidemiology, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
Abstract:   (4706 Views)

Background and Aims: Acurate measurements of variables are crucial in epidemiological studies. Therefore, even the best design cannot prevent bugs caused due to the lack of reliability and validity measurement in studies. The aim of this study is to determine the validity of teeth-canal measurement.

Materials and Methods: This methodological study used available data of patients referred to dental clinics at Hamadan University of Medical Sciences in Hamadan with sample size or 58 cases in 2012. In order to determine the reliability of measuring the length of canals and introduce the most appropriate measure met of the actual data, Bland-Altman plot and intraclass correlation coefficient (ICC) were used and finally compared.

Results: In this study, the mean ± SD of channel length in the apex locator Root ZX were 21.93 ± 2.28 mm and in X-ray PA were 22.4 ± 2.38 mm. ICC between the length of canals by the apex locator and radiographic in all teeth was 0.989. Bland-Altman plot showed that absolute agreement between the two methods of measurement.

Conclusion: The findings of this study ensure dental professionals that measuring the length of channels by PA method is more practical and easier and prove different approaches of the reliability and validity. However, we recommend using ICC and Bland Altman methods due to their informative nature and consideration of absolute agreement instead of consistency.

Full-Text [PDF 581 kb]   (2534 Downloads)    
Type of Study: Research | Subject: general
Received: 2017/04/5 | Accepted: 2017/04/5 | Published: 2017/04/5

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb