<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی میزان از دست دادن گشتاور در اباتمنت‌‌‌های زیرکونیایی MAD/MAM و پیش‌ساخته تیتانیومی</title_fa>
	<title>Evaluation of torque loss value of MAD/MAM zirconia abutments with prefabricated titanium abutments</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; در پاسخ به نیاز‌‌‌های زیبایی بیماران، استفاده از اباتمنت‌‌‌های سرامیکی گسترش یافته است. علی‌رغم زیبایی این اباتمنت‌‌‌ها، دقت ماشین کاری و تطابق آن‌‌ها همواره مورد سوال بوده است. هرگونه عدم تطابق در محل اتصال بین اباتمنت و ایمپلنت، درنهایت منجر به از دست دادن گشتاور و شل شدن پیچ اباتمنت می‌گردد. هدف از این مطالعه بررسی و مقایسه میزان از دست دادن گشتاور اولیه در اباتمنت‌‌‌های زیرکونیایی&lt;br&gt;manually aided design/manually aided manufacture (MAD/MAM) و پیش‌ساخته تیتانیومی بود.&lt;p&gt;&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; هفت عدد اباتمنت تیتانیومی (Branemark RP, Easy abutment) تهیه گردید. برای ساخت اباتمنت‌‌‌های سرامیکی، از تکنیک copy milling (MAD/MAM) استفاده شد و با دوپلیکیت کردن اباتمنت‌‌‌های تیتانیومی هفت عدد اباتمنت زیرکونیایی (ZirkonZahn, Sand in Taufers, Italy) تهیه شد. اباتمنت‌‌‌های هر دو گروه، ابتدا با گشتاور 35 Ncm بر روی مدل ایمپلنت محکم شدند و پس از 10 دقیقه مجدداً گشتاور با همان مقدار اولیه، اعمال گردید. سپس اباتمنت‌‌‌ها با Torque controller باز شده و مقادیر عددی detorque را در هر نمونه توسط تورک متر دیجیتالی به صورت درصدی از گشتاور ابتدایی ثبت گردید. آنالیز آماری توسط t-test صورت گرفت.&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;یافته‌‌‌ها:&lt;/strong&gt; میانگین از دست دادن گشتاور در اباتمنت‌‌‌های از پیش‌ساخته 71/12 Ncm با انحراف معیار 70/1 و برای اباتمنت‌‌‌های سرامیکی MAD-MAM، 50/15 Ncm با انحراف معیار 67/4 بود که از لحاظ آماری تفاوت معنی‌داری بین دو گروه وجود نداشت (23/0P=).&lt;/p&gt;&lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; باتوجه به محدودیت‌‌‌های این مطالعه، می‌توان نتیجه گرفت که بین میزان detorque در اباتمنت‌‌‌های سرامیکی از نوع MAD/MAM و تیتانیومی تفاوتی وجود ندارد.&lt;/p&gt;&lt;/span /&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;TEXT-ALIGN: justify&quot;&gt;&lt;strong&gt;Background and Aims:&lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments.&lt;/p&gt;&lt;p style=&quot;TEXT-ALIGN: justify&quot;&gt;&lt;strong&gt;Materials and Methods: &lt;/strong&gt;Seven titanium abutments (Branemark RP, Easy abutment) and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy) were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student&#039;s t test.&lt;/p&gt;&lt;p style=&quot;TEXT-ALIGN: justify&quot;&gt;&lt;strong&gt;Results: &lt;/strong&gt;The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23).&lt;/p&gt;&lt;p style=&quot;TEXT-ALIGN: justify&quot;&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments.&lt;/p&gt;</abstract>
	<keyword_fa>از دست دادن گشتاور,اباتمنت زیرکونیا,اباتمنت تیتانیومی</keyword_fa>
	<keyword>Torque loss,Zirconia abutment,Titanium abutment</keyword>
	<start_page>48</start_page>
	<end_page>54</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-7&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Marzieh</first_name>
	<middle_name></middle_name>
	<last_name>Alikhasi</last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی‌خاصی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Roshanak</first_name>
	<middle_name></middle_name>
	<last_name>Baghaie</last_name>
	<suffix></suffix>
	<first_name_fa>روشنک </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بقایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>سایر</affiliation_fa>
	 </author>


	<author>
	<first_name>Nasim</first_name>
	<middle_name></middle_name>
	<last_name>khosronejad</last_name>
	<suffix></suffix>
	<first_name_fa>نسیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خسرونژاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Pooya </first_name>
	<middle_name></middle_name>
	<last_name>Aslani</last_name>
	<suffix></suffix>
	<first_name_fa>پویا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اصلانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email> pooyaaslani@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
