<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>27</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی ریزنشت ترمیم‌های کلاس V کامپوزیت در دندان‌های پرمولر با و بدون استفاده از جریان الکتریسیته حین اعمال مواد باندینگ عاجی مختلف در محیط آزمایشگاه</title_fa>
	<title>Evaluation of class V composite restorations microleakage in premolars with/without electric current while applying variant dentin bondings</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; زمینه و هدف: &lt;/strong&gt;برای موفقیت ترمیم‌های کامپوزیتی در جلوگیری از ریزنشت درحد فاصل کامپوزیت و دندان نیاز به وجود سیل مطلوب توسط ماده باندینگ است. هدف از این تحقیق بررسی ریزنشت ترمیم‌های کلاس V در دندان‌های پرمولر با و بدون استفاده از جریان الکتریسیته حین اعمال مواد باندینگ عاجی مختلف در محیط آزمایشگاه بود . &lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; روش بررسی: &lt;/strong&gt;در این تحقیق از 120 دندان پرمولر سالم که به دلایل ارتودنسی کشیده شدند ، استفاده شد و به منظور ضدعفونی دندان‌ها به مدت 24 ساعت در هیپوکلریت سدیم قرار داده شدند. در تمامی دندان‌ها حفرات کلاس V روی سطوح باکال تراشیده شدند. ریشه دندان‌ها در فاصله 5 میلی‌متری از CEJ توسط دیسک قطع شده و بافت پالپی خارج شد. دندان‌ها به 6 گروه 20 تایی تقسیم شدند. در گروه او ل ( 3M ESPE, St Paul, MN, USA) Single bond با اعمال جریان الکتریسیته با یک حرکت جارویی پیوسته به عنوان کاتد و اسفنج حاوی ماده باندینگ به عنوان آند استفاده شد. شدت جریان به کار رفته µA 15 بود و در گروه دوم Single bond بدون جریان الکتریسیته به کار برده شد. سپس باندینگ‌های PQ1 (Ultradent, Germany) و Optibond solo plus &lt;br&gt;(Kerr, USA) نیز با و بدون جریان الکتریسیته به کار برده شدند. بعد از کاربرد باندینگ و کیور ماده باندینگ مطابق دستور کارخانه، ترمیم دندان‌ها توسط کامپوزیت Valux Plus انجام شد و کامپوزیت، کیور و سپس توسط دیسک، پرداخت شد. کانال توسط موم چسب سیل شد و تمام سطوح دندان به جز 1 میلی‌متر اطراف ترمیم با لاک پوشانده شد، سپس تحت 1000 سیکل ترموسیکل (Fuel engineering LTD, Iran) بین 5 درجه و 55 درجه سانتی‌گراد با&lt;br&gt;Dwell time 5 ثانیه قرار گرفتند. نمونه‌ها 24 ساعت در فوشین قرارداده شدند. برای مشاهده زیر میکروسکوپ برش‌های فاسیو لینگوالی داده شده و توسط استریو میکروسکوپ با بزرگنمایی 40 × بررسی شدند، بررسی ریزنشت بر طبق نفوذ رنگ در مارجین ژنژیوالی با رتبه‌بندی از 4- 0 انجام شد . نتایج به دست آمده توسط تست Mann-Whitney و تست کروسکال- والیس ارزیابی شد . &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; یافته‌ها: &lt;/strong&gt;براساس نتایج به دست آمده، ریزنشت ترمیم ها در گروه‌هایی که از جریان الکتریکی برای اعمال ماده باندینگ استفاده شد ب ه صورت معنی‌داری کمتر از گروه‌های بدون استفاده از جریان الکتریکی بود (05/0 P= ). کمترین میزان ریزنشت در گروه PQ1 با جریان الکتریسیته دیده شد، بیشترین تفاوت در حالت با و بدون جریان الکتریسیته نیز در گروه PQ1 دیده شد و بعد از آن Single bond و Optibond solo plus در حالت با جریان ریزنشت کمتری نشان دادند. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt; &lt;strong&gt; نتیجه‌گیری: &lt;/strong&gt;استفاده از جریان الکتریسیته در طول استفاده از باندینگ‌های دندانی می‌تواند باعث کاهش میکرولیکیج شود که این مساله به وسیله نفوذ رنگ مشخص شد. &lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt; &lt;strong&gt; Background and Aims: &lt;/strong&gt;The ability of composite restorations to prevent microleakage needs desirable bonding material for proper sealing . The purpose of this study was to evaluate class V composite restorations microleakage in premolars with/without electric current while applying variant dentin bonding in vitro. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; Materials and Methods: &lt;/strong&gt;120 non-carious human premolars were used for this study and standardized class v cavities were prepared. The tooth roots were cut by discs at a distance of 5 mm from CEJ and pulp tissue was removed. The teeth were divided into six groups of 20. In the first group, electric current was applied, Single bond (3M ESPE, St Paul, MN, USA) with a broom motion attached to the cathode and a sponge containing bonding was used as anode. The used current was 15µA and the Single bond in the second group was used without electricity. Then two bondings PQ1 (Ultradent, Germany) and Optibond solo plus (Kerr, USA) were used with and without electricity. After adhesive application and curing the bonding agents, cavities were restored by a composite (Valux Plus). The root ends were sealed by wax and all teeth surfaces, except 1 mm around the restorations were covered with a nail varnish. The specimens were thermocycled for 1000 cycles and placed in fushin for 24 hours and were then sectioned vertically and examined under a stereomicroscope. Data were scored on a 0-4 scale based on microleakage at the gingival margins and analyzed using Kruskal-Wallis and Mann-whitney test. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; Results: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;Based on the results, the extent of microleakage in the groups of electric current was significantly less than the groups without using the electric current (P=0.05). The lowest degree of microleakage was found in PQ1 group, and the greatest difference between the groups with and without electricity was also found in PQ1 group. Single bond and Optibond Solo Plus with electric &lt;strong&gt;&lt;/strong&gt;current showed a lower degree of microleakge. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; Conclusion: &lt;/strong&gt;The result showed that use of electric &lt;strong&gt;&lt;/strong&gt;current during the application of dental adhesives could reduce the extent of microleakage. &lt;/p&gt;</abstract>
	<keyword_fa>باندینگ دندان, کامپوزیت, ترمیم</keyword_fa>
	<keyword>Dental bonding, Composite, Restoration</keyword>
	<start_page>99</start_page>
	<end_page>107</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-746&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Narges </first_name>
	<middle_name></middle_name>
	<last_name>Dorri</last_name>
	<suffix></suffix>
	<first_name_fa>نرگس </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Narges.dorri@yahoo.com:</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی   دانشگاه علوم پزشکی جندی شاپور اهواز</affiliation_fa>
	 </author>


	<author>
	<first_name>Azita </first_name>
	<middle_name></middle_name>
	<last_name>Kaviani</last_name>
	<suffix></suffix>
	<first_name_fa>آزیتا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاویانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی   دانشگاه علوم پزشکی جندی شاپور اهواز</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali </first_name>
	<middle_name></middle_name>
	<last_name>Noori</last_name>
	<suffix></suffix>
	<first_name_fa>علی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده پزشکی    دانشگاه علوم پزشکی جندی شاپور اهواز</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
