<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مطالعه پروفایلومتری و میکروسکوپ الکترونی اثر پرداخت بر خشونت سطحی دو نوع کامپوزیت (با بیس سایلوران و متیل متاکریلات) و یک نوع گلاس آینومر</title_fa>
	<title>Profilometeric and SEM evaluation of effect of polishing on surface roughness of two composites (silorane-based and methylmethacrylate-based) and a Glass Ionomer</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه&lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;&lt;strong&gt;و&lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;&lt;strong&gt;هدف&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; هدف از مطالعه حاضر بررسی اثر پرداخت بر خشونت سطحی کامپوزیت با بیس سایلوران و مقایسه آن با کامپوزیت با بیس متاکریلات و یک نوع گلاس‌آینومر به وسیله پروفایلومتری و مطالعه با میکروسکوپ الکترونی (SEM) بود.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;روش&lt;/strong&gt;&lt;strong&gt; &lt;/strong&gt;&lt;strong&gt;بررسی&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; برای هرکدام از مواد مورد مطالعه (کامپوزیت Filltek P90، کامپوزیت Filtek P60 و گلاس‌آینومر Fuji IX) 28 نمونه تهیه شد. آماده‌سازی نمونه‌ها در مولد پلی‌اتیلن با قطر 4 میلی‌متر و ارتفاع 10 میلی‌متر انجام شد. نیمی از نمونه‌های هر ماده توسط کاغذ سنباده 180 grit از جنس سیلیکون کارباید و در حضور آب اتمام (finish) شد. سطح نیمی دیگر از نمونه‌ها ابتدا با کاغذ سنباده 180 grit و سپس به ترتیب با کاغذ سنباده‌های 250، 400، 800، 1000، 2000 و 2500 grit و در حضور آب پرداخت گردید. خشونت سطحی نمونه‌ها توسط پروفایلومتر تماسی بررسی شد و مقادیر متوسط خشونت سطحی (R&lt;sub&gt;a&lt;/sub&gt;) و حداکثر خشونت سطحی (R&lt;sub&gt;max&lt;/sub&gt;) توسط دستگاه مشخص گردید. سپس از هر 6 گروه مورد مطالعه، 4 نمونه به صورت تصادفی انتخاب گردید و تحت میکروسکوپ الکترونی FE-SEM سطح آنها بررسی شد. آنالیز آماری توسط آزمون t، آنالیز واریانس و آزمون Dunnett T3 انجام شد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; در هر 3 ماده، Ra بین 180 و 2500grit  متفاوت بود. در 180 grit، Ra تنها بین Filtek P60 و Fuji IX اختلاف معنی‌داری داشت (01/0P=). Ra با استفاده از سمباده 2500grit  تنها بین Filtek P90 و Filtek P60 تفاوت معنی‌داری نشان نداد (56/0P=).&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; در گلاس‌آینومر و ترمیم‌های کامپوزیتی خلفی مرحله پرداخت توصیه می‌شود.&lt;/p&gt;                                                                  &lt;/span&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Background and Aims:&lt;/strong&gt; To evaluate the effect of polishing on surface roughness of silorane-based composite using profilometery and Scanning Election Microscopy (SEM) and compare it with that of a methylmethacrylate-based composite and a glass ionomer.&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this study, 3 groups (n=28) were tested: specimens of two composites (Filtek P90 and Filtek P60) and a glass ionomer (Fuji IX) which were prepared in polyethylene molds (4 mm diameter×10 mm height). Half of the specimens in each group were finished with 180-grit silicon carbide paper and the remaining were finished with 180-grit, and subsequently polished with 250, 400, 800, 1000, 2000, and 2500-grit silicon carbide papers. The surface roughness was evaluated using a contact profilometer and then mean (R&lt;sub&gt;a&lt;/sub&gt;) and maximum (R&lt;sub&gt;max&lt;/sub&gt;) of surface roughness were recorded. Then, the surface of 4 specimens of each subgroup was observed under SEM. Statistical analysis was performed with T-test, ANOVA and Dunnett T3 tests.&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; In all materials, Ra was different between polishing with 180 and 2500-grit silicon carbide papers. In 180-grit group, only R&lt;sub&gt;a&lt;/sub&gt; of Filtek P60 and Fuji IX showed significant difference (P=0.01). In 2500-grit group, there was no significant difference between the Ra of Filtek P60 and Filtek P90 (P=0.56).&lt;/p&gt;
&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Polishing is recommended for the glass ionomer and posterior composite restorations.&lt;/p&gt;</abstract>
	<keyword_fa>کامپوزیت,پرداخت,گلاس‌آینومر</keyword_fa>
	<keyword>Composite,Polishing,Glass Ionomer</keyword>
	<start_page>33</start_page>
	<end_page>41</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-5&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Masumeh</first_name>
	<middle_name></middle_name>
	<last_name>Hasani Tabatabaei</last_name>
	<suffix></suffix>
	<first_name_fa>معصومه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسنی طباطبایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Sakine</first_name>
	<middle_name></middle_name>
	<last_name>Arami</last_name>
	<suffix></suffix>
	<first_name_fa>سکینه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ayob</first_name>
	<middle_name></middle_name>
	<last_name>Pahlavan</last_name>
	<suffix></suffix>
	<first_name_fa>ایوب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پهلوان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Esmaeil</first_name>
	<middle_name></middle_name>
	<last_name>Yasini</last_name>
	<suffix></suffix>
	<first_name_fa>اسماعیل</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mansoure</first_name>
	<middle_name></middle_name>
	<last_name>Mirzae</last_name>
	<suffix></suffix>
	<first_name_fa>منصوره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid</first_name>
	<middle_name></middle_name>
	<last_name>Kermanshah</last_name>
	<suffix></suffix>
	<first_name_fa>حمید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرمانشاه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Farnaz</first_name>
	<middle_name></middle_name>
	<last_name>Farahat</last_name>
	<suffix></suffix>
	<first_name_fa>فرناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فراهت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>farnazfarahat@ssu.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید صدوقی یزد</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
