<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1384</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2006</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>18</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)</title_fa>
	<title>Evaluation of two electronic apex locator of 4th generation, Raypex4 and Apit7, in canal length determination</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;rtl&quot; align=&quot;right&quot;&gt;&lt;font face=&quot;tahoma,arial,helvetica,sans-serif&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; اندازه‌گیری دقیق طول کارکرد در درمانهای ریشه از اهمیت بالایی در موفقیت درمان برخوردار است. چنانچه این اندازه‌گیری با دقت انجام نگیرد، مقداری از نسج پالپ در کانال ریشه باقی می‌ماند و یا کار درمان ورای کانال ریشه با تجاوز به محدوده پریودنتال صورت می‌گیرد که هر دو حالت می‌تواند توأم با عدم موفقیت باشد. مطالعه حاضر با هدف مقایسه دقت دو دستگاه آپکس یاب الکترونیکی (EAL) از نسل چهارم یعنی Apit7 (یک دستگاه شناخته شده) با دستگاه جدید Raypex4 در اندازه‌گیری طول واقعی (Actual Length: AL) و طول کارکرد (Working Length: WL) در بیماران و مقایسه نتایج حاصله با اندازه‌گیری عینی این دندانها پس از خارج نمودن آنها انجام شد.&lt;br&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه که به روش بررسی تست‌های تشخیصی انجام شد، 32 دندان تک‌کانال توسط دو دندانپزشک که به صورت مستقل با یکی از دستگاه‌های EAL کار می‌کردند، مورد بررسی قرار گرفتند. این دندانها پس از کشیده ‌شدن تمیز و کدگذاری شده و برای بار سوم به طور عینی توسط یک اندودنتیست طول واقعی و طول کارکرد آنها اندازه‌گیری و یادداشت شد. این تحقیق در تمام مراحل تا بررسیهای آماری به صورت کور انجام گرفت. پس از تعیین درصد دقت، با استفاده از آزمون توزیع دو جمله‌ای، درصد دقت دستگاه‌ها با یکدیگر مقایسه شدند. 05/0P&lt; به عنوان سطح معنی‌داری در نظر گرفته شد.&lt;br&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; دقت دستگاه Raypex4 در تعیین طول واقعی، نسبت به مشاهده عینی در محدوده 5/0± میلیمتر 8/68% و در محدوده 1± میلیمتر 3/83% بود. با پذیرش خطای 5/0+ تا 1- میلیمتر، دقت در اندازه‌گیری AL حدود 1/75% در مقایسه با مشاهده عینی بود. دقت این دستگاه در تعیین طول کارکرد نسبت به مشاهده عینی با محدوده 5/0± میلیمتر، 8/68% و با 1± میلیمتر 3/84% بود. با پذیرش خطای 5/0 تا 1- میلیمتر 9/71% بود. دقت دستگاه Apit7 در تعیین طول واقعی نسبت به مشاهده عینی 7/65% در فاصله 5/0± میلیمتر و در فاصله 1± میلیمتر 3/78% بود. با پذیرش خطای 5/0 تا 1- میلیمتر، دقت دستگاه Apit7 8/78% بود. در تعیین طول کارکرد با محدوده 5/0± میلیمتر، دقت 6/62% و در 1± میلیمتر، دقت 3/81% و در فاصله 5/0+ تا 1- میلیمتر، دقت 1/75% بود. نتایج اختلاف آماری معنی‌داری را بین دو دستگاه نشان نداد (05/0(P&gt;؛ در حالی که در مقایسه با اندازه‌گیری عینی نیز از دقت بالایی برخوردار نبود.&lt;br&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; دقت دو دستگاه اندازه‌گیری تقریباً مشابه یکدیگر بود؛ ولی در مجموع هیچ ‌یک به تنهایی کافی و مورد اطمینان نبود.&lt;br&gt;&lt;/font&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this test evaluation study performed at Dental School of Tehran University, a total of 32 single canal vital teeth planned for extraction because of orthodontic and prosthetic reasons were selected. Working length determination by each of the two electronic apex locators was performed by two different dentists. These measurements were compared with direct visual measurement after tooth extraction. The dentists working with devices and the endodontist who determined the working length of the extracted teeth as well as the statistician, all were blind regarding the results. The data were compared using binominal distribution test with P&lt;0.05 as the limit of significance. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The accuracy of actual length determination of Raypex4 was 68.8% in the limit of ± 0.5 and 83.3% in the limit of ±1. From the actual length measurements, 75.1% were within the tolerance of +0.5 to-1. The accuracy of the working length determination by Raypex4 was 68.8% within the tolerance of ± 0.5 and 84.3% within the tolerance of ± 1. Taking the tolerance of + 0.5 to -1 mm into account, the accuracy of the instrument was about 78.8%. The accuracy of actual length determination of Apit7 was 65.7% in the limit of ±0.5 and 78.3% in the limit of ±1. Compared to the visual length determination, 78.8% of the actual length measurements were within the tolerance of +0.5 to-1. The accuracy of the working length determination was 62.6% within the tolerance of ±0.5 and 81.3% within the tolerance of ±1. Taking the tolerance of + 0.5 to -1 mm into account, the accuracy of the instrument was about 75.1%. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Raypex4 and Apit7 had similar accuracy in determining the actual length. However, they still can not replace the routine methods of actual length determination. &lt;/p&gt;</abstract>
	<keyword_fa>اندازه‌گیری طول کانال، دستگاه های آپکس یاب الکترونیکی، Raypex4, Apit7</keyword_fa>
	<keyword>Electronic apex locators,Root length determination,Apit7,Raypex4</keyword>
	<start_page>6</start_page>
	<end_page>12</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-292&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Vahid </last_name>
	<suffix></suffix>
	<first_name_fa>علویه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وحید</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Bahraminia </last_name>
	<suffix></suffix>
	<first_name_fa>احمد </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهرامی‌نیا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>MJ</first_name>
	<middle_name></middle_name>
	<last_name>Kharazi Fard </last_name>
	<suffix></suffix>
	<first_name_fa>محمدجواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> خرازی‌فرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
