<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1385</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2006</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی مقاومت به شکست دندانهای ترمیم شده با کامپوزیت Packable و هیبرید</title_fa>
	<title>Fracture resistance of teeth restored with packable and hybrid composites</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;rtl&quot; align=&quot;right&quot;&gt;&lt;font face=&quot;tahoma,arial,helvetica,sans-serif&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; عرفی کامپوزیت‌های packable در سالهای اخیر، امکان ترمیم دندانهای خلفی با این مواد را فراهم آورده است. هرچند کاهش انقباض پلیمریزاسیون و نزدیکی ضریب انبساط حرارتی آنها به دندان، استرس وارده به ساختمان دندان را کاهش می‌دهد؛ اما ویسکوزیتۀ بالا، ممکن است سبب تطابق کمتر شود؛ بنابراین به طور واضح نمی‌دانیم که آیا این مواد می‌توانند سبب استحکام ساختمان دندان شوند یا خیر؟ هدف از مطالعه حاضر ارزیابی مقاومت به شکست دندانهایی است که به روشهای مختلف جایگزینی و curing، با کامپوزیت packable یا هیبرید ترمیم شده‌اند.&lt;br&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه تجربی- مداخله‌ای 75 دندان پره‌مولر سالم به صورت تصادفی به 5 گروه 15 تائی تقسیم شدند.گروه اول به عنوان گروه کنترل در نظر گرفته شد و بر روی بقیۀ دندانها ابتدا حفرات مزیواکلوزودیستال مشابه یکدیگر تراش داده شد. در گروه دوم، دندانها با کامپوزیت اسپکتروم (هیبرید) به روش incremental و با شدت نوری 2mw/cm500 پر شدند. در گروه سوم، از کامپوزیت (packable) Surefil ، با روش incremental و شدت نوری mw/cm500 استفاده شد. دندانهای گروه چهارم و پنجم با کامپوزیت Surefil و روش bulk پر شدند. با این تفاوت که در گروه چهارم شدت نوری 2mw/cm500 و در گروه پنجم روش&lt;br&gt;ramp (2mw/cm900-100) به کار رفت. بعد از ترموسایکل، نیروی مقاومت به شکست توسط Universal Testing Machine ارزیابی شد. برای تعیین درجۀ تبدیل مونومر به پلیمر (DC یا Degree of Conversion) در عمیق‌ترین ناحیه از روش FTIR (Fourier Transformation Infrared) استفاده شد که روش کار در گروه‌های مورد آزمایش (A-D) مشابه با گروه‌های آزمایش مقاومت به شکست (2-5) بود. از آزمون آنالیز واریانس یک طرفه و Tukey HSD برای بررسی نتایج استفاده و 05/0P&lt; به عنوان سطح معنی‌داری در نظر گرفته شد.&lt;br&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; مقاومت به شکست در گروه کنترل به صورت معنی داری بیش از سایر گروه‌ها بود؛ ولی در بین گروه‌های ترمیم شده تفاوتی از لحاظ آماری وجود نداشت. DC برای کامپوزیت اسپکتروم به طور قابل توجهی بیشتر از Surefil بود. روش bulk و شدت نوری 2mw/cm500 سبب کاهش DC گردید. DC در روش bulk و شدت نوری بالا به روش ramp با روش incremental و شدت نوری 2mw/cm500 تفاوت معنی داری نداشت.&lt;br&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; روش جایگزینی، شدت و نحوه تابش و نوع کامپوزیت بر مقاومت دندانها به شکست، اثری نداشت. استفاده از کامپوزیت packable به روش bulk و با شدت نور 2mw/cm 500 یا کمتر در حفرات به عمق 4 میلیمتر و یا بیشتر به دلیل عدم حصولDC مناسب توصیه نمی‌شود.&lt;/font&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; With recent introduction of packable composites, it is claimed that they apply less stress on tooth structure because of reduced polymerization shrinkage, and similarity of coefficient of thermal expansion to tooth structure. However, the high viscosity may in turn cause less adaptation, so it is not clearly known whether these materials strengthen tooth structure or not. The aim of this study was to evaluate fracture resistance of maxillary premolars, receiving hybrid or packable composite restorations with different methods of application and curing. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this experimental study, seventy five intact premolars were randomly assigned to five groups of 15 teeth each. One group was maintained intact as the control group. Similar MOD cavities were prepared in the other teeth. The teeth in group two were restored with Spectrum in incremental layers and light cured with 500 mw/cm2 intensity. The third group were filled with Surefil and cured with light intensity of 500 mw/cm2. The groups four and five were restored with Surefil in bulk technique with two different modes: 500 mw/cm2 intensity and a ramp mode (100-900 mw/cm2) respectively. After thermocycling, force to fracture was assessed and degree of conversion (DC) at the bottom of cavities was evaluated for different modes and methods. The curing and placement methods in groups tested for DC (A to D) were the same as fracture resistance groups (2 to 5). Data were analyzed using one way ANOVA and Tukey HSD tests with p&lt;0.05 as the limit of significance. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; All the restored groups showed significantly less fracture resistance than the control group, but had no significant difference among themselves. DC of Spectrum was higher than Surefil. Bulk method with 500 mw/cm2 light intensity, significantly decreased DC. DC in bulk method with high light intensity was not significantly different from incremental method with 500 mw/cm2 light intensity. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Placement techniques, light intensity and type of composite had no influence on the fracture resistance. The use of packable composite with bulk technique and 500 mw/cm2 intensity or less is not recommended in 4 mm depth cavities due to insufficient DC. &lt;/p&gt;</abstract>
	<keyword_fa>کامپوزیت هیبرید،کامپوزیت packable،مقاومت به شکست،دزجه تبدیل مونومر به پلیمر،روش لایه گذاری،روش bulk</keyword_fa>
	<keyword>Hybrid composite,Packable composite,Bulk technique,Incremental technique</keyword>
	<start_page>16</start_page>
	<end_page>25</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-281&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Ghavam </last_name>
	<suffix></suffix>
	<first_name_fa>مریم </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قوام</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Ataee </last_name>
	<suffix></suffix>
	<first_name_fa> محمد </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عطائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>F.</first_name>
	<middle_name></middle_name>
	<last_name>Fallahzade </last_name>
	<suffix></suffix>
	<first_name_fa> فرنوش </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فلاح زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
