<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Dental Medicine</title>
<title_fa>مجله دندانپزشکی</title_fa>
<short_title>J Dent Med-tums</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jdm.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1024-641X</journal_id_issn>
<journal_id_issn_online>2008-2444</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1386</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2007</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>20</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی کارائی دستگاه‌های لایت‌کیور در مطب‌های دندانپزشکی خصوصی شهر تهران در سال 1384</title_fa>
	<title>Evaluation of curing units used in private dental offices in Tehran in 2005</title>
	<subject_fa>عمومی</subject_fa>
	<subject>general</subject>
	<content_type_fa>تحقیقی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; کاربرد کامپوزیت‌ها و مواد ترمیمی با نور سخت شونده در دندانپزشکی رواج زیادی یافته است. موفقیت ترمیم‌‌های انجام شده تا حدود زیادی بستگی به کارائی مناسب دستگاه‌های لایت‌کیور شامل شدت اشعه خروجی و طول موج دستگاه دارد. مطالعه حاضر با هدف ارزیابی کارایی دستگاه‌های لایت‌کیور در مطب‌های دندانپزشکی خصوصی شهر تهران در سال 1384 انجام شد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;روش‌ بررسی:&lt;/strong&gt; در این مطالعه توصیفی- تحلیلی مقطعی، دستگاه‌های لایت‌کیور 240 مطب دندانپزشکی شهر تهران به طور تصادفی مورد بررسی قرار گرفتند. شدت اشعه توسط دستگاه رادیومتر و میزان دبری جمع شده روی fan دستگاه و وجود خراش یا ترک بر روی فیلتر از طریق بررسی و مشاهده مستقیم دستگاه ثبت شد. سن دستگاه، تعداد دفعات تعویض لامپ و رضایت دندانپزشک از دستگاه از طریق پرسش از افراد در فرم‌های مخصوصی درج گردید. داده‌ها به کمک نرم‌‌افزار SPSS و با استفاده از آزمون ضریب همبستگی اسپیرمن و آزمون t مورد  تحلیل آماری قرار گرفتند. 05/0&gt;P به عنوان سطح معنی‌داری در نظر گرفته شد.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;یافته‌ها: &lt;/strong&gt;شدت اشعه 8/53% دستگاه‌ها بیشتر از mW/cm&lt;sup&gt;2&lt;/sup&gt; 300 بود که این شدت اشعه مطلوب می‌باشد. شدت اشعه 4/30% دستگاه‌ها بین mW/cm&lt;sup&gt;2&lt;/sup&gt; 201 تا 300 و شدت اشعه 8/15% از دستگاه‌های لایت کیور mW/cm&lt;sup&gt;2&lt;/sup&gt; 200 و کمتر از آن بود. در ضمن بین میزان نور خروجی دستگاه با افزایش سن دستگاه و یا افزایش دفعات تعویض لامپ، یا خش دار بودن فیلتر و یا افزایش دبری بر روی fan رابطه‌ای منفی وجود داشت.&lt;/p&gt;  &lt;p dir=&quot;rtl&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; طبق یافته‌های این مطالعه شدت اشعه دستگاه‌های لایت کیور در 2/46% مطب‌های دندانپزشکی برای کیورینگ مناسب نبوده و از آنجایی که با افزایش سن دستگاه و یا افزایش دفعات تعویض لامپ و یا افزایش میزان دبری بر روی fan  دستگاه و یا وجود خراش بر روی فیلتر از شدت اشعه کاسته می‌شود، بنابراین کنترل منظم کیفیت این دستگاه­ها از اهمیت ویژه‌ای برخوردار است.&lt;/p&gt;                                                                  &lt;/span&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; Light cured composites and other restorative materials are quite common in dentistry today. Successful restorations are dependent on efficiency of curing light unit, eg. the intensity of emitted light and its wave length. The aim of this study was to evaluate the efficiency units of curing, in private dental offices in Tehran. &lt;/p&gt;&lt;p&gt;&lt;strong&gt;Materials and Methods:&lt;/strong&gt; In this descriptive cross sectional study, light curing devices in 240 private dental offices were evaluated randomly. Light intensity was measured by radiometer, debris on the fan and cracks and scratches on the filter were directly observed and the age of the device, frequency of changing the bulb and satisfaction of the dentist with regard to the light curing unit were recorded in a questionnaire. Data were analyzed using Spearman and t test, with p&lt;0.05 as the level of significance.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results showed that 53.8% of the units had intensities more than 300 mW/cm&lt;sup&gt;2&lt;/sup&gt;. The intensity of 30.4% of curing light units were between 20 and 300 mW/cm&lt;sup&gt;2&lt;/sup&gt; and 15.8% had intensities lower than 200 mW/cm&lt;sup&gt;2&lt;/sup&gt;. There was a negative relation between light intensity and the age of the unit, frequency of bulb changing or scratches on the filter and debris on the fan.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; The results of this study showed that the light intensities of about 46% of light curing units used in private dental practices and clinics were inadequate. Since factors like aging of the curing light unit, frequent bulb changing, increasing the amount of debris on the fan and scratches on the filter reduce the light intensity, regular quality control of these devices is essential.&lt;/p&gt;</abstract>
	<keyword_fa>دستگاه لایت‌کیور،شدت نور،رادیومتر،کامپوزیت نوری</keyword_fa>
	<keyword>Light curing unit; Intensity; Radiometer; Composite resin</keyword>
	<start_page>138</start_page>
	<end_page>143</end_page>
	<web_url>http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-226&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaei </last_name>
	<suffix></suffix>
	<first_name_fa>منصوره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>N.</first_name>
	<middle_name></middle_name>
	<last_name>Moradimajd </last_name>
	<suffix></suffix>
	<first_name_fa>نیما</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مرادی مجد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
